PERPUSTAKAAN SEKOLAH TINGGI ILMU KESEHATAN SAMARINDA
REPOSITORY
Select Language

Simple Search

Advanced Search
Title :
Author(s) :
  • SEARCHING...

Subject(s) :
  • SEARCHING...

ISBN/ISSN :
GMD : Collection Type : Location :
License

This Software is Released Under GNU GPL License Version 3.

indexed
Visitors
Flag Counter

Statistic
Total Collection:
Title Marmara Pharmaceutical Journal of Research in Pharmacy Journal of Research in Pharmacy 2024 , Vol 28 , Issue 3
Edition 2024 , Vol 28 , Issue 3
Call Number
ISBN/ISSN
Author(s)
Subject(s) Tenofovir
entecavir
ethylenediamine sulfonamide polymer resin
graphene
voltammetry
Classification
Series Title
GMD Karya Tulis Ilmiah
Language Indonesia
Publisher marmara University
Publishing Year 2024
Publishing Place
Collation
Abstract/Notes ABSTRACT: The combination of entecavir (ETV) and tenofovir (TEV), nucleos(t)ide analogs (NUCs), is advised as first-
line treatment for people suffering from multidrug-resistant hepatitis B due to their favorable safety profile, low side-
effect rate, and high genetic barrier. This study reports the fabrication of a novel cross-linked ethylenediamine

sulfonamide polymer resin (EDASP) and graphene (Gr)-modified carbon paste electrodes (CPE) for the simultaneous
determination of the anti-HBV drugs ETV and TEV in bulk and dosage form by differential pulse voltammetry (DPV).
The electrodes were specified through cyclic voltammetry, Fourier transform infrared (FTIR), scanning electron
microscopy (SEM), and the analytical parameters were optimized. The findings indicate that both drugs displayed clear
oxidation peaks on the Gr-CPE and EDASP-CPE electrodes at pH 4.5 and 4.0, respectively, in the Britton-Robinson
buffer. The linear dynamic range of ETV and TEV was determined between 1μM and 250μM on both working electrodes
by DPV. The limit of detection (LOD) and limit of quantification (LOQ) for ETV were 0.2μM and 0.6μM, respectively,
on Gr-CPE. The LOD and LOQ for TEV were 0.2μM and 0.7μM, respectively. The novel EDASP-CPE exhibited
improved sensitivity with LOD and LOQ for ETV of 0.2μM and 0.5μM, respectively. The LOD and LOQ for TEV on
EDASP CPE were 0.2μM and 0.7μM, respectively. The proposed method was successfully applied to the simultaneous
determination of ETV and TEV in a commercial tablet dosage form, exhibiting good accuracy and precision. The results
highlight the potential of the novel cross-linked ethylenediamine sulfonamide polymer resin-modified carbon paste
electrode for the simultaneous determination of anti-HBV drugs in dosage form by differential pulse voltammetry.

KEYWORDS: Tenofovir, entecavir, ethylenediamine sulfonamide polymer resin, graphene, modified carbon paste
electrode, voltammetry, pharmaceutical preparation.
Specific Detail Info
Image
File Attachment
LOADING LIST...
Availability
LOADING LIST...
  Back To Previous